
Tanks in immersion service demand linings engineered for the specific chemistry they hold. We deliver corrosion protection that extends asset life and protects what is inside.
Before a lining goes on, the tank has to be sound. We repair and restore tanks, addressing corrosion, pitting, weld seams, and substrate damage, so the new lining bonds to a surface that will hold. Repairing and relining is a fraction of the cost of replacing a tank.
Blast, treat, and rebuild corroded and pitted steel before lining.
Address failed weld seams and joints that leak or undermine the lining.
Restore the tank floor and walls to a sound profile for proper adhesion.
Find and seal leaks, then reline for long-term containment.
Abrasive blasting and profiling to the standard the lining system requires.
Holiday testing and documentation that the repair and lining meet spec.
Field-spray applications depend on the applicator and the weather to hit proper ratio and thickness. Robotically pre-manufactured polyurea liners are produced in a controlled factory environment and arrive fully cured, with verified thickness and QA before they ever reach the jobsite, removing the variables that cause field-applied liners to fail.
Produced and verified in a controlled environment, not subject to field weather or applicator variability.
Every liner arrives at a documented, consistent mil thickness, no thin spots or over-spray.
A monolithic polyurea barrier engineered for immersion and containment service.
Arriving fully cured means faster install and quicker return to service than field spray.
For tanks and infrastructure that store or contact drinking water, we apply NSF/ANSI 61-certified linings, the national standard that confirms a coating will not leach harmful contaminants into potable water. We line potable water tanks, reservoirs, and storage for municipal water systems, water districts, and treatment facilities.
Interior linings for elevated, ground-storage, and standpipe drinking-water tanks using NSF/ANSI 61-certified systems.
Certified linings for finished-water reservoirs and clearwells at treatment plants.
Work delivered to municipal and AWWA standards with documentation for owners and inspectors.
Only NSF/ANSI 61-listed coating systems, applied to manufacturer specification, for drinking-water contact.
Tell us about your facility and the surfaces you need protected. We respond within one business day and can schedule an on-site evaluation, including moisture testing, at no cost.